GL-P2C
Triaxial Accelerograph
Main Application Fields:
1. Strong earthquake observation in free field;
2. Strong vibration observation and health monitoring of buildings and structures;
3. Observation of manual blasting;
4. Vibration monitoring of dams, Bridges, stations, tunnels and other facilities;
5. Site seismic safety assessment, etc
6.Emergency mobile earthquake observation;earthquake scientific investigation;earthquake early warning monitoring;land slide and rock fall monitoring;
OVERVIEW
Description
The GL-P2C Seismic Intensity Meter incorporates a high-sensitivity triaxial MEMS accelerometer, featuring an embedded Linux operating system with LAN interface connectivity. It supports network configuration through external 4G wireless routers and boasts built-in 8GB storage for network synchronization. With compact design and low power consumption, this device integrates advanced functionalities including automatic seismic event detection, intensity calculation, and real-time estimation of TC/Pd parameters. Capable of generating continuous waveform data, it automatically transmits earthquake-triggered alerts, intensity measurements, and instrument status via network or SMS, complemented by localized audio alarms. The large-format color LCD screen displays real-time waveforms, operational parameters, and seismic data, making wall-mounted installation effortless.
Technical Parameter
sensor
● Bandwidth: DC-80Hz;
● Dynamic range: more than 90dB;
● Full scale: 2g;
DA
● ADC: 24 bits;
● Sampling rate: 50sps, 100sps, 200sps, 500sps;
● Digital filter: linear phase FIR, minimum phase FIR;
time service
● Timing: network timing;
● Time synchronization error: less than 0.05mS;
● Clock stability: better than 0.5ppm;
data recording
● Storage medium: 8GB CF card;
● Recording method: event trigger recording, continuous waveform recording;
● Event trigger: STA/LTA, level, timing;
● Data format: EVT, mini SEED;
data communication interface
● Interface: LAN Ethernet, RS-232 serial interface;
● Protocol: TCP/IP;
Overall machine performance
● Output sensitivity: 500count/gal;
● Diagnosis and alarm: the automatic diagnosis system voltage, record line zero voltage, charging status, time setting status, available data storage space and ambient temperature, etc. Trigger or diagnose errors automatically alarm;
● Data transmission mode: real-time data flow, support multiple connections;
● Power supply: external power supply +12V (10V–20V), average power consumption about 2W;
● Working environment: temperature: -20℃ –60℃, relative humidity: 98%;
● Size: 220mm×150mm×50mm;
● Weight: 1.9kg.